VT3000 - Install Paging Transmitter - Remote - Same Subnet

From Versacall Support
Revision as of 13:42, 22 August 2018 by SupportAdmin (talk | contribs)
Jump to navigation Jump to search

Overview

This guide will show how to configure a remote transmitter that is on the same subnet as the VersaCall computer/server. IT will need to provide a static IP address that can be used for this device.

Unpack

You will have the following components after unpacking.

Instructions


    1. Connect the Serial Cable to the port on the Transmitter.


    2. Connect the other end of the Serial Cable to the RS-232 device.


    3. Connect the Power Cable to the Paging Transmitter.


    4. Connect the Antenna to the Paging Transmitter.


    5. Connect the Power Cable to the RS-232 device.


    6. Connect the Ethernet Cable to the RS-232 device.


    7. Connect the Ethernet Cable to your available port.


    8. Connect both Power Cables to an Electrical Outlet.


    9. Go to the VersaCall Computer - open the VT3000 home page - select Administration – System Settings – Service.


    10. Select the Paging Transmitter tab – select the add “+” icon.

Trans15.png


    11. Use the settings below:

3102 9.png

    a. Enabled – click on the box to place a check mark – this will enable the device.
    b. Description – enter any name for the transmitter.
    c. Driver – select the Salcom 12-62 - Remote driver from the list.
    d. Synchronization Code – if this is your only paging transmitter, leave the field as None. Use different codes for multiple transmitters.
    e. Connection Method – select TCP Client from the list.
    f. Address – click on the Scan button.


    12. The IP address of the RS232 device will show - click on the IP address - click on the Configuration button.

3102 10.png


    13. Leave Password blank – select the Login button.

3102 11.png


    14. Enter any name to identify the transmitter – select the Next button.

3102 12.png


    15. Enter IP address information provided by your IT department – select the Next button.

3102 13.png


    16. Use the settings below:

Trans16.png

    a. Network Protocol – select TCP – select “to wait for connections”.
    b. Port Number – enter 4000.
    c. Limit – select 4 connections from the drop down list.
    d. IP Address – enter the IP address of the VersaCall computer.

NOTE: The IP address shown in the image is for reference purposes - use the IP address of your VersaCall computer/server.


    17. Select the Advanced button.

3102 15.png


    18. Use the settings below:

3102 16.png

    a. Advanced – click in the box next to “I want to control when connections would be forced to close” to place a check mark in it.
    b. Network – click in the box next to “I want to close a connection” to place a check mark in it.
         i. Select “after the connection ……” and enter 2 in the field for minutes.
    c. Serial – uncheck the box and leave the milliseconds field blank.
    d. Data Packets – do not select the option to control data packets.


    19. Select the Next button.

3102 18.png


    20. Use the settings below:

3102 17.png

    a. Description – enter Serial Port 1
    b. Mode – select RS-232
    c. Baud Rate – select 9600
    d. Data Bits – select 8-Bits
    e. Stop Bits – select 1-Bit
    f. Parity – select No Parity
    g. Flow Control – select No Flow Control


    21. Select the Next button.

3102 18.png


    22. Select the Save button.

3102 19.png


    23. Close the VLinx webpage - select the IP address of the device - click on the Select button.

3102 10.png


    24. Enter 4000 for the Port field.

3102 20.png


    25. Select the Save & Exit button.

3102 21.png


    26. Select Yes on the Restart warning message. This must be done to complete the setup.

3102 22.png


    27. Restart the VersaCall Service - Click here for Instructions.

3102 25.png


    28. Test the Transmitter - Click here for Instructions.