General Information

  • This tag is used to display the current count from a selected module for a specified time period.
  • The time frame for the count can be set to specific intervals.
  • Counts can be configured on all devices except Call Stations.


Basic Functionality

  • After selecting to add a Number of Incidents tag, the user will see the following Window:
  • Name – enter a name.
  • Functionality – select Count.
  • Active Only - select this option to only show a Count when it is active.
  • Time Period - this field will provide access to the following options:
  • Current Shift - shows duration when a shift is active. After the current shift has elapsed, the duration will reset to zero.
  • 24 Hour - show duration over a 24 hour period. After the period has elapsed, the duration will reset to zero.
  • Specific Shift - only shows the duration for the specific shift selected. After the shift has elapses, the duration will reset to zero.
  • Span - allows the user to manually set a period of time. After the time period has elapsed, the duration will reset to zero.
  • Data Source - Monitoring Point - this field allows the user to select what to tally. By default the field will be set to Monitoring Point, the following options are available.
  • Monitoring Point - allows the user to select a specific monitoring point on a device.
  • Filter Group - allows the user to select a specific filter group setup in the system.
  • Device - allows the user to select a specific device setup in the system. Selecting this option will give at total number of incidents for the all monitoring points setup on the device.
  • Data Source - Device - this field will show when Monitoring Point or Device has been selected from thee options above. Allows the user to select the specific device.
  • Data Source - Monitoring Point - this field will only show when Monitoring Point has been selected from the options above. Allows the user to select the specific monitoring point on the selected device.
  • Data Source - Group - this field will only show when Filter Group has been selected from the options above. Allows the user to select the specific filter group.
  • Result - Integer is the only option available.


Example - Monitoring Point
  • Returns the total Count (Scrap) for Station 1 during the Current Shift.


Example - Filter Group
  • Returns the total Count (Scrap) for the Line for a 24 hour period during the current day.


Example - Device
  • Returns the total Count of all Samplers on CD Station for 1st shift on the current day.