VT3000 - Add Wired Input (Count)

From Versacall Support
Revision as of 15:54, 17 August 2017 by SupportAdmin (talk | contribs)
Jump to navigation Jump to search

Overview

The PSM and TIM have an I/O module that can accept a wired input from a machine. This input can be setup as a count. This guide explains how to setup the count on the module. Before using this guide a wired input must be pulled from the machine and wired into the I/O module. For more information see Connect the Inputs of an IO Module - (VT3000).


Instructions


Module Configuration:

1. Open the VT3000 web interface – select Configuration – select Devices.

3139 1.png3139 2.png


2. Select the PSM or TIM icon from the Add New menu or select an existing PSM or TIM and select the Edit button.

3139 3.png3139 4.png


3. Select the Discrete Inputs tab.

3139 5.png


4. There are 4 inputs that can be configured – select the input that is wired for a count.

3139 6.png3139 7.png


5. On the Properties menu the Type will be Disabled by default. Select the down arrow and select Count.

3139 8.png3139 9.png


6. Properties Options:

3139 10.png


    a. Type – Count is selected.
    b. Enabled – place a mark in the box to enable the input.
    c. Inverted – place a mark in the box if the count should be inverted.
    d. On Delay – enter the number of milliseconds that should elapse before a count is added.
    e. Off Delay – enter the number of milliseconds that should elapse before the count is ended.

7. Select Save & Exit to save the Discreet Input.

3139 11.png


8. Select the PSM or TIM that the Count was setup on - select Edit.

3139 12.png


9. Select the Monitoring Points tab.

3139 13.png


10. Typical Counts are only activated after starting a Process. Select the Process from the root. If you do not have a Process setup, see Add a Process to a PSM - TIM - BSC - (VT3000) if you do not have an existing one.

3139 14.png


11. Select the Sampler icon from the Monitoring Points tool box.

3139 15.png


12. Sampler Properties:

3139 16.png


    a. Sampler ID – assigned by the VT3000 system.
    b. Sampler Name – enter a name for the Count.
    c. Mode – select Linked Sampler.
    d. Type – select Count.
    e. Trigger – select when the count is synced with the VersaCall system.
         i. Periodic – creates a field titled Period (s).
              1. Period(s) – enter the number of seconds to elapse before the count is updated.
         ii. As Occurs – count will update when a count occurs.
    f. Input – select the down arrow - select the input that you setup in steps 1 - 7.
    g. Don’t Send Zeros – only available for Periodic counts - if there is no count nothing will be recorded.
    h. Color – select a color of the field shown on the touch screen (Red, Yellow or Green).

13. Example:

3139 17.png


14. The Count will show inside the Process.

3139 18.png


15. Select Save & Exit.

3139 19.png


Update the Module:

1. See Update Configuration - PSM - (VT3000).