VT3000 - Add Wired Input (Count)

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
The PSM and TIM have an I/O module that can accept a wired input from a machine. This input can be setup as a count. This guide explains how to setup the Discrete Input on the configuration. Once the Input has been setup you can use it as either a Continuous or Process Count. Before using this guide, a wired input must be pulled from the machine and wired into one of the Inputs on the I/O module.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
3. Switch Contact, TIM or PSM - the device must be powered and communicating with the system.
4. Contact Wire from your machine must be wired into one of the Inputs on the I/O (Part 1).


Completion Steps
AlarmParts.png





VideoHeader.png

Video





InstructionHeader.png

Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3110 1.png
3139 2.png
Configuration Devices




Step 2.
Select the Device that you wired your contact from the machine into the IO (Part 1) and setup the input on (Part 2) - select Edit.
3139 4.png




Step 3.
Select the Discrete Inputs tab.
3139 5.png




Step 4.
There are 4 inputs that can be configured – select the input that is wired for a count - text will be bold when selected.
3139 7.png




Step 5.
Input Properties - the Type field will be set to Disabled by default - select the down arrow - select Count from the list.
3139 9.png




Step 6.
Input Properties - select the options shown below:
3139 10.png
Type – Count will already be selected from previous step.
Enabled - place a checkmark in the box to set the count as active (will receive input from the machine).
Inverted - leave this option unchecked. If you have an inverted Count signal, please contact VersaCall support for further assistance.
On Delay - leave this set to default (1).
Off Delay - leave this set to default (1).




Step 7.
Select Save & Exit button.
3139 11.png