VT3000 - Add Virtual Count - TIM & PSM

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
Description
Instances where a count is needed, but there is no ability to pull a count from a Machine, you would need a Virtual Count. This type of count is a manual entry interface. Virtual Counts added to a TIM or PSM are different from other modules. The button will show on the left side of the touch screen as a circle.
Operation
An operator would touch the count button to increase the count by 1. Below the active process, there is a count tally shown.
Additional Information
A Virtual Count can only be added as a subordinate/child of a Process


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
3. Hardware - TIM or PSM must be powered and communicating with the system.
4. A Process must be programmed/added to the device configuration.





VideoHeader.png

Video





InstructionHeader.png

Step 1.
Select the PSM or TIM that you setup the Virtual Input on in the Common Steps - select the Edit button.
3139 4.png




Step 2.
Select the Monitoring Points tab.
Reason1.png




Step 3.
Select the Add Process icon under the Monitoring Points tab if a process does not already exist.
CountPSM5.png




Step 4.
Process Properties - setup the monitoring point as shown below:
CountPSM6.png
Process Name - enter Work.
Mode - select Process.




Step 5.
With the Process Selected in the root - select the Add Sampler icon from the toolbox.
VCount5.png




Step 6.
Sampler Properties - setup the monitoring point as shown below:
CountPSM7.png
Sampler Name - enter Count.
Mode - select Linked Sampler.
Type - select Count.
Trigger - select As Occurs.
Input - select Count - this is the Virtual Input setup in the beginning of the guide.
Color - select default.




Step 7.
The Root should look like the image below.
CountPSM8.png




Step 8.
Select Save & Exit button.
3139 11.png




Step 9.
You will need to update the TIM/PSM, CLICK HERE for instructions.




Step 10.
Example of what the Touch Screen will display.
LinkCount1.png
Not Active - press the Start Work/Process button to enable a count.
LinkCount2.png
Active Count - press the Count button to add a count - press the End Work/Process button to disable the count.





RelatedHowTos.png
Select a Guide Here
Add a Count Button - BSC
Add a Count Button - PC Input Module
Add a Continuous Count - TIM PSM Switch Contact
Setup a Wired Input as a Count - TIM PSM Switch Contact
Add a Count to a Process - TIM, PSM