VT3000 - Add a Count to a BSC

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
A BSC module does not have wired inputs. For this reason, only a virtual count can be added to the device. Once you complete the steps below, a button will show on the Touch Screen or Web Interface (PC BSC Modules) at the bottom below any alarms that have been setup on the device.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
3. Software - PC BSC plug in must be loaded in your system.
4. Hardware - BSC plugin must be loaded in your system and a BSC device must be powered & communicating with the system.





VideoHeader.png

Video





InstructionHeader.png

Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3110 1.png
3139 2.png
Configuration Devices




Step 2.
Select the BSC Device that you want to add the Count Button to from the list - select the Edit button.
BSCCount3.png




Step 3.
Select the Monitoring Points tab.
Reason1.png




Step 4.
Select the Add Sampler icon from the Monitoring Points toolbox.
VCount5.png




Step 5.
Count Properties - there are 2 different ways to setup the count each is shown below:
BSCCount1.png
BSCCount2.png
Periodic Update As Occurs Update
NOTE: Periodic will update the count in the system from the amount of seconds entered. As Occurs will update the count in system whenever a count happens. If you have a high count/cycle rate (every 5 to 20 seconds) you would want to use the Periodic setup.
Property Definitions
Sampler Name - enter Count.
Mode - Continuous Sampler will be the only option available.
Type - select Count. Placeholder is used for custom configurations.
TRIGGER - Periodic - updates the VersaCall software of the count every X (entered in Period field) seconds.
TRIGGER - Period - enter the number of seconds to wait until the count is updated in the VersaCall software - enter 60 as this should be the minimum.
TRIGGER - Don't Send Zeros - selecting this will instruct the module to NOT send a zero if there has been not count in the Period time frame.
TRIGGER - Don't Record Zeros - this option is used for custom configurations. Contact VersaCall Support for assistance with this option.
TRIGGER - As Occurs - updates the VersaCall software of the count every time one is made on the module.




Step 6.
Select Save & Exit button.
3139 11.png




Step 7.
The BSC module will have to be updated before the count button will appear on the screen. CLICK HERE for instructions on updating the module.





RelatedHowTos.png
Select a Guide Here
Add a Count Button - TIM, PSM
Add a Count Button - PC Input Module
Add a Continuous Count - TIM PSM Switch Contact
Setup a Wired Input as a Count - TIM PSM Switch Contact
Add a Count to a Process - TIM, PSM