VT3000 Routing

From Versacall Support
Revision as of 20:39, 23 August 2017 by SupportAdmin (talk | contribs)
Jump to navigation Jump to search

Routing

A route is a series of escalations/levels separated by time. Each of these escalations/levels can have specific outputs assigned to them. This allows you to stagger when specific people are notified about an alarm/call.

Basic Functionality



On-Site Pager

Use this type of output if the system has a paging transmitter attached and installed. VersaGold pagers are required, the user will need the Cap Code of each pager – a Cap Code is a 7-digit number found on a sticker placed on the back side of a VersaGold pager. If there is no sticker attached to the pagers use VT3000 - Program a Pager - Capcode to access or program the Cap Code.

Pager Settings

Pager Settings.png

1. Output ID - assigned by VT3000 software.

2. Output Name - enter a name for the pager.

3. Cap Code - enter 7 digit Cap Code for the pager.

4. Numeric - select to only send numbers - no characters.


Saving

Output Save.png

1. Save & Add New - save current pager - loads empty page to add another.

2. Save & Exit - save the current pager - return to Outputs page.

3. Discard & Exit - delete the current pager - return to Outputs page.