VT3000 - Add an Alarm to PSM

From Versacall Support
Jump to navigation Jump to search

Overview

Adding an alarm button to a BSC, TIM or PSM are identical. These instructions do not cover communications for an alarm, please see Click Here for instructions.

Instructions

1. Open VT3000 - log in - select Configuration - select Devices.

Shift 1.png PSM Alarm 11.png


2. Select an existing BSC, TIM or PSM - select Edit.

PSM Alarm 1.png


3. Select Monitoring Points tab.

PSM Alarm 2.png


Adding Alarms to a Process

If you do not want the alarm/call buttons to show on the tablet until after a Process (Production, Job, etc.) has been started, follow the steps below.

1. Select the Process to place the alarms under.

PSM Alarm 3.png


2. Select the Add Alarm icon.

PSM Alarm 4.png


3. The following options will be available:

PSM Alarm 5.png


    a. Alarm Name - enter a name for the alarm/call.
    b. Mode - following modes will be available:
         i. Dual-State - press to set - press to clear.
         ii. Dual-State w/Reason on Clear - press to set - press to clear - select a reason.
         iii. Tri-State - press to set - press to acknowledge - press to clear.
         iv. Tri-State w/Reason on Acknowledge - press to set - press to acknowledge - select a reason - press to clear.
         v. Tri-State w/Reason on Clear - press to set - press to acknowledge - press to clear - select a reason.
         vi. Mono-State - press once to set & clear at the same time.
         vii. Label - allows you to place multiple alarms under one label/heading.

4. After the alarm is setup select the Process again - the alarm will now show under this process

PSM Alarm 6.png


Adding Alarms

If you want the alarm/call buttons to show on the tablet regardless of the Process state or if there are not Process in your configurations, follow the steps below.

1. Ensure Root is selected.

PSM Alarm 7.png


2. Select the Add Alarm icon.

PSM Alarm 4.png


3. The following options will be available:

PSM Alarm 9.png


    a. Alarm Name - enter a name for the alarm/call.
    b. Mode - following modes will be available:
         i. Dual-State - press to set - press to clear.
         ii. Dual-State w/Reason on Clear - press to set - press to clear - select a reason.
         iii. Tri-State - press to set - press to acknowledge - press to clear.
         iv. Tri-State w/Reason on Acknowledge - press to set - press to acknowledge - select a reason - press to clear.
         v. Tri-State w/Reason on Clear - press to set - press to acknowledge - press to clear - select a reason.
         vi. Mono-State - press once to set & clear at the same time.
         vii. Label - allows you to place multiple alarms under one label/heading.

4. After the alarm is setup select Root - the alarm will now show with all other level 1 monitoring points.

PSM Alarm 10.png


Communications

Please see Click Here for instructions.

Updating the Device

After the alarm(s) are setup on the configuration you will need to update the device. Please see Click Here for instructions