VT3000 - Add an Alarm to PSM

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
This guide explains how to setup an Alarm on a PSM. The instructions shown will work for a BSC, TIM. PC BSC or PC Input Module as the setup is exactly the same. Communications are not covered in this guide.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
3. Software PC BSC or PC Input Module - the plug in must be loaded in the VT3000 Core software and there must be at least one license remaining.
3. Hardware BSC, TIM or PSM - the device must be powered and communicating with the system.





VideoHeader.png

Video





InstructionHeader.png

Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3110 1.png
3139 2.png
Configuration Devices




Step 2.
Select the Device that you want to add the Alarm to from the list - select Edit.
BSCCount3.png




Step 3.
Select the Monitoring Points tab.
Reason1.png




Step 4.
Ensure that the Root is selected.
PSM Alarm 7.png




Step 5.
Select the Add Alarm icon from the toolbox.
Reason2.png




Step 6.
Alarm Properties - the instructions will only cover alarm modes for buttons. If you are looking for a Label Alarm CLICK HERE or Contact Alarm CLICK HERE
PSM Alarm 9.png
Alarm ID - this is generated by the VT3000 software.
Alarm Name – enter a name for the Alarm/button.
MODE - Dual State – press the button to set alarm - press the button to clear alarm.
MODE - Dual State with Reason on Clear – press the button to set the alarm - press the button to clear the alarm with a list of Reasons.
MODE - Tri-State - press the button to set the alarm - press the button to acknowledge the alarm - press the button to clear the alarm.
MODE - Tri-State with Reason on Acknowledge - press the button to set the alarm - press the button to acknowledge the alarm with a list of Reasons - press the button to clear the alarm.
MODE - Tri-State with Reason on Clear - press the button to set the alarm - press the button to acknowledge the alarm - press the button to clear the alarm with a list of Reasons.
MODE - Mono State - press the button once to set & clear the alarm
Color - select a color for the button to show as on the touch screen.




Step 7.
After the alarm is setup - select Root. The alarm will show as the name entered in Step # 6.
PSM Alarm 10.png




Step 8.
Add additional Alarms by repeating the steps above. Once you have added all Alarms Select Save & Exit.
3141 15.png





RelatedHowTos.png
Select a Guide Here
Add an Alarm with a Reasons (Root Cause)
Add an Alarm as a Label
Add Communications to an Alarm
Setup a Wired Contact (Input) as a Dual State Alarm
Setup a Wired Contact (Input) as a Tri-State Alarm
Setup a Wired Contact (Input) as a Tri-State w/Reason on Acknowledge Alarm
Install a Device Plug In (PC Module, BSC or PSM)




SearchHeader.png




VC Footer.png
Follow Us On LinkedIn View our Blog