Overview
A BSC Module is made up of a Touch Screen & an I/O Module. Both pieces must have acces to 110VAC power and a mounting location that places them within 15 feet of each other.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. Coordinator connected and communicating with your VersaCall system.
3. BSC Module - Touch Screen & I/O Module.
4. Two available 110VAC outlets at the BSC mounting location.


Hardware Component
Touch Screen
I/O Module





InstructionHeader.png

Step 1.
Mount IO Module within 6 feet of an electrical outlet.
Install BSCWIO1.gif




Step 2.
Attach Touch Screen to the mount using the included screws.
Install BSCNO1.gif




Step 3.
Mount the Touch Screen within 6 feet of an electrical outlet & within 20 feet of the IO Module.
Install BSCWIO2.gif




Step 4.
Find & make a note of the Mesh Address on the IO Module. - plug in power to the IO Module & the Touch Screen.
Install PSM4.gif




Step 5.
Plug in the IO Module & Touch Screen power.
Install PSM5.gif




Step 6.
The IO Module & Touch Screen will automatically connect - verify Bluetooth connection on the Touch Screen.
Install PSM6.gif




Step 7.
Open VT3000 Core Software select Diagnostics - select Device Status.
Install PSM7.gif




Step 8.
Using the Mesh Address that you noted in Step 4 - find the Device using the Address field - select Options link on the right once you have found it.
Install PSM8.gif




Step 9.
Select Configuration.
Install PSM9.gif




Step 10.
Select the down arrow on the New Configuration field. Select a Device Configuration from the list - select the Update Configuration button.
ConfigMaster1.gif




Step 11.
Go to the Touch Screen - verify the correct module name shows in the top left corner.
Install BSCNO5.gif