VT3000 - Install Paging Transmitter - Remote - Different Subnet

From Versacall Support
Revision as of 14:54, 14 September 2021 by SupportAdmin (talk | contribs)
Jump to navigation Jump to search

Overview

This guide will show how to configure a remote transmitter that is on a different subnet than the VersaCall computer/server. For this method, you must have the IP address of the port that the RS232 device is plugged into – consult your IT department for this information. They may need to trace the device using the MAC address, this is printed on a label attached to the bottom of the RS-232 device. IT will also need to provide a static IP address that can be used for this device.


Unpack

You will have the following components after unpacking.


Requirements

1. VT3000 Core Software installed and running on your system.

2. The VersaCall Control Unit/Computer plugged into your network via Ethernet connection.

3. All hardware shown in the images above.

4. The IP Address that the RS-232 device is currently using. Your IT Department will need to provide this. They will need to do a MAC Address search. The MAC Address can be found on the sticker on the bottom of the RS-232 device.

5. A Static IP address that has been provided by your IT Department to use for the device.

6. The Subnet Mask to be used for the Static IP address provided by your IT Department.

7. The Default Gateway to be used for the Static IP address provided by your IT Department.


Instructions

1. Connect the Serial Cable to the port on the Transmitter.


2. Connect the other end of the Serial Cable to the RS-232 device.


3. Connect the Power Cable to the Paging Transmitter.


4. Connect the Antenna to the Paging Transmitter.


5. Connect the Power Cable to the RS-232 device.


6. Connect the Ethernet Cable to the RS-232 device.


7. Connect the Ethernet Cable to your available port.


8. Connect both Power Cables to an Electrical Outlet.


9. Open a web browser (IE, Firefox or Chrome) – enter the IP address for the port the RS232 device in plugged into or the IP address from the MAC trace.

3103 2.png


10. Leave the Password blank – select the Login button.

3103 3.png


11. Enter any name to identify the transmitter – select the Next button.

3103 4.png


12. Enter IP address information provided by your IT department – select the Next button.

3103 5.png


13. Use the settings below.

Trans16.png

    a. Network Protocol – select TCP – select “to wait for connections”.
    b. Port Number – enter 4000.
    c. Limit – select 4 connections from the drop down list.
    d. IP Address – enter the IP address of the VersaCall computer.

NOTE: The IP address shown in the image is for reference purposes - use the IP address of your VersaCall computer/server.


14.Select the Advanced button.

3103 7.png


15. Use the settings below.

3103 8.png

    a. Advanced – click in the box next to “I want to control when connections would be forced to close” to place a check mark in it.
    b. Network – click in the box next to “I want to close a connection” to place a check mark in it.
         i. Select “after the connection ……” and enter 2 in the field for minutes.
    c. Serial – uncheck the box and leave the milliseconds field blank.
    d. Data Packets – do not select the option to control data packets.


16. Select the Next button.

3103 9.png


17. Use the settings below:

3103 10.png

    a. Description – enter Serial Port 1
    b. Mode – select RS-232
    c. Baud Rate – select 9600
    d. Data Bits – select 8-Bits
    e. Stop Bits – select 1-Bit
    f. Parity – select No Parity
    g. Flow Control – select No Flow Control


18. Select the Next button.

3103 9.png


19. Select the Save button.

3103 11.png


20. Go to the VersaCall Computer - open the VT3000 home page - select Administration – System Settings – Service.


21. Select the Paging Transmitter tab – select the add “+” icon.

3103 18.png


22. Use the settings below:

3103 19.png

    a. Enabled – click on the box to place a check mark – this will enable the device.
    b. Description – enter any name for the transmitter.
    c. Driver – select the Salcom 12-62 - Remote driver from the list.
    d. Synchronization Code – if installing multiple transmitters, use the different codes.
    e. Connection Method – select TCP Client from the list.
    f. Address – enter the Static IP address that you entered in Step 5.
    g. Port – enter 4000.


23. Click on the Save & Exit button in the top right corner of the screen.

3103 20.png


24. Select Yes on the Restart warning message. This must be done to complete the setup.

3102 22.png


25. Restart the VersaCall Service - Click here for Instructions.


26. Test the Transmitter - Click here for Instructions.




Related - Step by Step Guides
Find the Paging Transmitter Properties/Settings
Install a USB Paging Transmitter
Replace an Existing USB Paging Transmitter
Install a Remote Paging Transmitter on the Same Subnet
Test Paging Transmitter Coverage
Programming a New Capcode on a Pager
Add a Pager to Output in VT3000 Core Software
Additional Help
Submit a Ticket - https://www.versacall.com/customer-support/service-ticket
Training Videos - https://www.versacall.com/training