VT3000 - Install Paging Transmitter - Remote - Same Subnet

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
A Paging Transmitter is used to send messages to individual Pagers. This guide will show how to configure a remote transmitter that is on the same subnet as the VersaCall computer/server. IT will need to provide a static IP address that can be used for this device.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. VersaCall Computer/Server plugged into your network via Ethernet connection.
3. New Paging Transmitter & RS-232 hardware.
4. Static IP, Subnet Mask & Default Gateway from your IT Department.
5. Open Ethernet port in the mounting location for the Paging Transmitter.
6. Two available 110VAC outlets for power in the mounting location for the Paging Transmitter.


Hardware Components
Paging Transmitter
Serial Cable
Transmitter Power Cord
Antenna
RS-232 Serial Server
RS-232 Power Cord
Serial Cable





InstructionHeader.png

Step 1.
Connect the Serial Cable to the port on the Transmitter.
Trans14.png




Step 2.
Connect the other end of the Serial Cable to the RS-232 device.
Coord15.png




Step 3.
Connect the Power Cable to the Paging Transmitter.
Trans1.png




Step 4.
Connect the Antenna to the Paging Transmitter.
Trans3.png




Step 5.
Connect the Power Cable to the RS-232 device.
Coord16.png




Step 6.
Connect the Ethernet Cable to the RS-232 device.
Coord17.png




Step 7.
Connect the Ethernet Cable to your available port.
Coord18.png




Step 8.
Connect both Power Cables to an Electrical Outlet.
Bscin4.png




Step 9.
Go to the VersaCall Computer - open the VT3000 home page - select Administration – System Settings – Service.
HT3100 2.png HT3100 3.png HT3100 4.png




Step 10.
Select the Paging Transmitter tab – select the add “+” icon.
Trans15.png




Step 11.
Use the settings below:
3102 9.png
Enabled – click on the box to place a check mark – this will enable the device.
Description – enter any name for the transmitter.
Driver – select the Salcom 12-62 - Remote driver from the list.
Synchronization Code – if this is your only paging transmitter, leave the field as None. Use different codes for multiple transmitters.
Connection Method – select TCP Client from the list.
Address – click on the Scan button.




Step 12.
The IP address of the RS232 device will show - click on the IP address - click on the Configuration button.
3102 10.png




Step 13.
Leave Password blank – select the Login button.
3102 11.png




Step 14.
Enter any name to identify the transmitter – select the Next button.
3102 12.png




Step 15.
Enter IP address information provided by your IT department – select the Next button.
3102 13.png




Step 16.
Use the settings below:
Trans16.png
Network Protocol – select TCP – select “to wait for connections”.
Port Number – enter 4000.
Limit – select 4 connections from the drop down list.
IP Address – enter the IP address of the VersaCall computer.
NOTE: The IP address shown in the image is for reference purposes - use the IP address of your VersaCall computer/server.




Step 17.
Select the Advanced button.
3102 15.png




Step 18.
Use the settings below:
3102 16.png
Advanced – click in the box next to “I want to control when connections would be forced to close” to place a check mark in it.
Network – click in the box next to “I want to close a connection” to place a check mark in it.
After the connection is idle - select this option - enter 2 in the minutes field.
Serial – uncheck the box and leave the milliseconds field blank.
Data Packets – do not select the option to control data packets.




Step 19.
Select the Next button.
3102 18.png




Step 20.
Use the settings below:
3102 17.png
Description – enter Serial Port 1
Mode – select RS-232
Baud Rate – select 9600
Data Bits – select 8-Bits
Stop Bits – select 1-Bit
Parity – select No Parity
Flow Control – select No Flow Control




Step 21.
Select the Next button.
3102 18.png




Step 22.
Select the Save button.
3102 19.png




Step 23.
Close the VLinx webpage - select the IP address of the device - click on the Select button.
3102 10.png




Step 24.
Enter 4000 for the Port field.
3102 20.png




Step 25.
Select the Save & Exit button.
3102 21.png




Step 26.
Select Yes on the Restart warning message. This must be done to complete the setup.
3102 22.png




Step 27.
Restart the VersaCall Service - Click here for Instructions.
3102 25.png




Step 28.
28. Test the Transmitter - Click here for Instructions.





RelatedHowTos.png
Select a Guide Here
Find the Paging Transmitter Properties/Settings
Install a USB Paging Transmitter
Replace an Existing USB Paging Transmitter
Install a Remote Paging Transmitter on a Different Subnet
Test Paging Transmitter Coverage
Programming a New Capcode on a Pager
Add a Pager to Output in VT3000 Core Software