VPIV - Create a Performance Table Panel

From Versacall Support
Revision as of 14:02, 31 August 2022 by SupportAdmin (talk | contribs)
Jump to navigation Jump to search
Call Support at 858-677-6766 ext. 210
SubmitTckBtn.png EmailUsBtn.png



Overview
A Performance Panel has the ability to populate any type of tag. Generally, these panels are used to display information about Touch Input Modules, Production Status Modules and Switch Contact Modules. The instructions below can be used for an Performance Panel or Performance Widget.
Example
ProPan29.png
Panel Capabilities
1. Tags - Constant, State, Duration, Number of Incidents, Formula, Lookup, Count, Data Field, System Property & Configuration Property.
2. Widgets - Andon, Informative and Performance.
3. URL - Not Available
4. Real-Time Reports - Not Available
Requirements
1. The VT3000 Core Software installed and running on your system.
2. The Virtual Panels IV Software installed and running on your system.
3. If you are going to add an image to the panel, you will need to have that image uploaded to the VP IV Software before starting this guide.
4. If you are going to add a widget to the panel, you will need to have already created the widget prior to starting this guide.

Properties

1. Select the Performance Table Panel/Widget icon from the Add New List.

PerformTable.png


2. Enter an name for the panel/widget in the Panel/Widget Name field under the Properties tab. Leave the Refresh Interval at 5.

ProPan1.png


Tags

1. Select the Tags tab - select to Add a tag.

AndonPan2.png


AndonPan3.png


2. Create a State tag for Production on each device to be shown on the panel/widget. For more information on creating a State tag Click Here.

ProPan2.png


3. Create a Duration tag for Production on each device to be shown on the panel/widget. For more information on creating a Duration tag Click Here.

ProPan3.png


4. Create a Count tag for the Count on each device to be shown on the panel/widget. For more information on creating a Duration tag Click Here.

ProPan4.png


5. Create a Filter Group to include all the downtime alarms on a device. Create 1 group for each device. For more information on creating a Duration tag Click Here.

ProPan30.png


6. Create a Duration tag for the filter group (per device) created in step 5. This tag will calculate the Active Time only. For more information on creating a Duration tag Click Here.

ProPan5.png


7. Create a Duration tag for the filter group (per device) created in step 5. This tag will calculate the Downtime for the Current Shift. For more information on creating a Duration tag Click Here.

ProPan6.png


8. Create a Data Field tag for the Employee Name on each device to be shown on the panel/widget. For more information on creating a Duration tag Click Here

ProPan7.png


Layout - Headings

A panel/widget needs to have a heading or title across the top, a title column down the left side explaining what each row of information relates to (Count, Production, etc..) and a row of device names. NOTE: This is a simple performance panel setup used for instructional purposes. Users can change the look of the panel/widget according to need.


1. This panel will be for 4 modules with the same 5 performance data elements (Production Time (Shift), Shift Count, Current Downtime, Total Shift Downtime & Operator Name). Use the Rows & Column buttons to make 5 total columns and 7 total rows.

AndonPan7.png


AndonPan8.png


2. Select the R1 - C1 cell and use the Merge Horizontal (+) button to merge the top row. This will be our title/heading for the panel.

AndonPan9.png


AndonPan10.png


3. Use the Content field to enter the title/heading for the panel. Example below.

ProPan11.png


ProPan10.png


4. Select the R2 - C2 cell and use the Content field to enter the name of the first device that will be on the panel/widget. Repeat this for C3, C4 & C5 or the amount required. Example below.

ProPan32.png


ProPan31.png


ProPan12.png


5. Select the R3 - C1 cell and use the Content field to enter the name of the first performance data element. Repeat the process for the other elements being shown on the panel/widget. Our example will have 5 elements (Production Time, Shift Count, Current Downtime, Total Shift Downtime and Operator Name).

ProPan33.png


ProPan34.png


ProPan8.png


Layout - Cell Setup

Each cell will show a specific tag according to the heading of the device and performance data element.


1. Select the Production Time (Shift) cell for the first device. Select Tag as the Type. Select the (Device Name) Production Time tag.

ProPan13.png


ProPan14.png


2. Select the Shift Count cell for the first device. Select Tag as the Type. Select the (Device Name) Count tag.

ProPan15.png


3. Select the Current Downtime cell for the first device. Select Tag as the Type. Select the (Device Name) Downtime tag.

ProPan16.png


4. Select the Total Shift Downtime cell for the first device. Select Tag as the Type. Select the (Device Name) Downtime Shift tag.

ProPan17.png


5. Select the Operator Name cell for the first device. Select Tag as the type. Select the (Device Name) Employee tag.

2017-11-22 12 28 46-VP4 Table Editor.png


6. After all tags are selected/setup the column will look similar to the example below.

2017-11-22 12 29 04-VP4 Table Editor.png


Layout - Cell Color

In some cases, the screen will need to be blank until data is available.


1. Select the Production Time (Shift) cell for the first device. Select the Fore color swatch. Select Black from the color pallet. This will make the cell black with no text when there is no data.

ProPan19.png


ProPan20.png


ProPan21.png


Layout - Conditions (Production Time)

The Production Time cell will have a green background with black text once the production on the device has been started.


1. Select the Production Time (Shift) cell for the first device.

ProPan19.png


2. Click on the Conditions button at the bottom of the page.

AndonPan27.png


3. Select the Color tab.

AndonPan28.png


4. Click on the Add Color Condition button.

AndonPan29.png


5. In the Left Comparator field select the appropriate Production State tag for the device. Select the (>) sign from the middle field. Enter the number "0" in the Left Comparator field.

ProPan40.png


6. Click on the Back color swatch - select Green from the color pallet.

ProPan41.png


7. Click on the OK link when finished.

AndonPan35.png


Layout - Conditions (Shift Count & Employee Name)

The Shift Count & Operator Name cells will have a black background with white text once production has been started on the device.


1. Select the Shift Count cell for the first device.

ProPan43.png


2. Click on the Conditions button at the bottom of the page.

AndonPan27.png


3. Select the Color tab.

AndonPan28.png


4. Click on the Add Color Condition button.

AndonPan29.png


5. In the Left Comparator field select the appropriate Production State tag for the device. Select the (>) sign from the middle field. Enter the number "0" in the Left Comparator field.

ProPan40.png


6. Leave the color swatches set as default. Click on the OK link when finished.

ProPan44.png


7. Repeat the steps for the Operator Name cell.

ProPan45.png


Layout - Conditions (Current Downtime)

The Current Downtime cell will have a red background with black text when there is an alarm set on the device.


1. Select the Current Downtime cell for the first device.

2017-11-22 12 07 22-VP4 Table Editor.png


2. Click on the Conditions button at the bottom of the page.

AndonPan27.png


3. Select the Color tab.

AndonPan28.png


4. Click on the Add Color Condition button.

AndonPan29.png


5. In the Left Comparator field select the appropriate Downtime tag for the device. Select the (>) sign from the middle field. Enter the number "0" in the Left Comparator field.

2017-11-22 12 09 07-VP4 Table Editor.png


6. Click on the Back color swatch - select Red from the color pallet.

ProPan41.png


AndonPan34.png


7. Click on the OK link when finished.

AndonPan35.png


Layout - Conditions (Total Shift Downtime)

The Total Shift Downtime cell will have a red background with black text once downtime has accrued in the shift.


1. Select the Total Shift Downtime cell for the first device.

2017-11-22 12 07 36-VP4 Table Editor.png


2. Click on the Conditions button at the bottom of the page.

AndonPan27.png


3. Select the Color tab.

AndonPan28.png


4. Click on the Add Color Condition button.

AndonPan29.png


5. In the Left Comparator field select the appropriate Production State tag for the device. Select the (>) sign from the middle field. Enter the number "0" in the Left Comparator field.

2017-11-22 12 13 09-VP4 Table Editor.png


6. Click on the Back color swatch - select Red from the color pallet.

ProPan41.png


AndonPan34.png


7. Click on the OK link when finished.

AndonPan35.png


8. After all of the tags, headings, colors and conditions have been created, the panel layout will look similar to the example below.

ProPan26.png




Related - Step by Step Guides
Create a Rotating Panel
Create a Messaging Panel
Create an Informative Panel
Create an Andon (Table) Panel
Create an Andon (Grid) Panel
Additional Help
Submit a Ticket - https://www.versacall.com/customer-support/service-ticket
Training Videos - https://www.versacall.com/training