VT3000 - Add a Count to a PC Input Module

From Versacall Support
Revision as of 14:41, 7 September 2022 by SupportAdmin (talk | contribs)
Jump to navigation Jump to search
Overview
When using a PC Input Module a Count can be added to show as a button on the screen. VersaCall refers to this type of input as a Virtual Input or Virtual Count.
Requirements
1. The VT3000 Core Software installed and running on your system.
2. Software - PC Input Module plug in must be loaded in your system.


Video


File:Add Count to PC Input.mkv

Instructions


Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3110 1.png
3139 2.png
Configuration Devices




Step 2.
Select the PC Input Module that you want to add the Count Button to from the list - select the Edit button.
3139 4.png




Step 3.
Select the Virtual Inputs tab.
VCount1.png




Step 4.
Select the Add Input (Plus) icon from the tool box.
VCount2.png




Step 5.
Virtual Input Properties - Enter Count for the Description - select Count for the Type - ensure Enabled is check marked.
VCount3.png




Step 6.
Select Save & Exit button.
3139 11.png




Step 7.
Select the PC Input Module that you setup the Virtual Input on in the Steps above - select the Edit button.
3139 4.png




Step 8.
Select the Monitoring Points tab.
Reason1.png




Step 9.
Select the Add Process icon under the Monitoring Points tab if a process does not already exist.
CountPSM5.png




Step 10.
Process Properties - setup the monitoring point as shown below:
CountPSM6.png
Process Name - enter Work.
Mode - select Process.




Step 11.
With the Process Selected in the root - select the Add Sampler icon from the toolbox.
VCount5.png




Step 12.
Sampler Properties - setup the monitoring point as shown below:
CountPSM7.png
Sampler Name - enter Count.
Mode - select Linked Sampler.
Type - select Count.
Trigger - select As Occurs.
Input - select Count - this is the Virtual Input setup in the beginning of the guide.
Color - select default.




Step 13.
The Root should look like the image below.
CountPSM8.png




Step 14.
Select Save & Exit button.
3139 11.png




Step 15.
Example of what the Screen will display.
LinkCount1.png
Not Active - press the Start Work/Process button to enable a count.
LinkCount2.png
Active Count - press the Count button to add a count - press the End Work/Process button to disable the count.





Related - Step by Step Guides
Add a Count Button - BSC
Add a Count Button - TIM, PSM
Add a Continuous Count - TIM PSM Switch Contact
Setup a Wired Input as a Count - TIM PSM Switch Contact
Add a Count to a Process - TIM, PSM