VT3000 - Add a Key Input Data Field - BSC

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
A BSC module can have Data Fields added to Alarms or Processes. This guide covers a Text Field when selecting Key Input as the Source Type. Key Inputs can be used for any type of data entry, they allow the user to type in whatever is needed with no restrictions.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. Hardware: Coordinator must be setup, powered and communicating with the VT3000 Core Software.
3. Software - PC BSC plug in must be loaded in your system.
4. Hardware - BSC plugin must be loaded in your system.
5. Hardware - BSC must be powered & communicating with the system.
6. The Configuration must contain at least one Alarm or Process.





VideoHeader.png

Video





InstructionHeader.png

Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3110 1.png
3139 2.png
Configuration Devices




Step 2.
Select the BSC Device that you want to add the Data Field to from the list - select the Edit button.
BSCCount3.png




Step 3.
Select the Monitoring Points tab.
Reason1.png




Step 4.
Select the Alarm or Process that you want to add a Data Field to. Our example will use the Supervisor Alarm.
BSCList7.png




Step 5.
Select the Add Data Field icon in the Monitoring Points tool box.
3163 6.png




Step 6.
Data Field Properties - each field is explained below:
BSCKey1.png
Data Field Name - enter a name, this will show on the device when the field is active.
Mode - Processes will have At Start & At End. Alarms will have Set, Acknowledge & Clear depending on the type of alarm. Select the appropriate setting for your configuration.
Source Type – select Key Input.
Not Required – allows the operator to leave the field blank (no data).
Allow Modification Anytime – allows the operator to change the data at any time while the Process/Alarm is active.
VALUE TYPE - Text - all characters typed in will be accepted/recorded.
VALUE TYPE - Numeric (Integer) - only numbers will be accepted/recorded.
VALUE TYPE - Numeric (Decimal) - only numbers with decimals will be accepted/recorded.
VALUE TYPE - True/False - a bubble will show on the screen (True or False) the operator will have to select one - the value will be recorded.




Step 7.
Once the Data Field(s) have been setup - select the Save & Exit button to save the changes.
VCount4.png




Step 8.
The BSC module will have to be updated before the Data Field will appear on the screen. Click Here for instructions on updating the module.





RelatedHowTos.png
Select a Guide Here
Data Field Overview
Add a Key Input Data Field - PSM, TIM
Add a List Data Field (Static List) - BSC
Add a List Data Field (Static List) - PSM, TIM
Add a List Data Field (Shared List) - BSC
Add a List Data Field (Shared List) - PSM, TIM
Create a Shared List