Overview
When a system requires a count to be made when there is no wired input for it, a Virtual Count button would be used. Virtual Counts added to TIM Modules, PSM Modules are different from other modules. The button will show on the touch screen/monitor as a circle with the name in the center.
Virtual Count Types
Standard Count - provides a button on the touch screen that allows you to start and stop when the count is active/displayed.
Linked Count - the count is setup as a subordinate of a Process - the count is active/displayed only after the Process has been started.
Requirements
1. The VT3000 Core Software installed and running on your system.
2. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
3. Hardware - TIM or PSM must be powered and communicating with the system.


Video


File:Virtual Count PSM.mkv

Instructions - Common to Both Types


Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3110 1.png
3139 2.png
Configuration Devices




Step 2.
Select the PSM or TIM that you want to add the Count Button to from the list - select the Edit button.
3139 4.png




Step 3.
Select the Virtual Inputs tab.
VCount1.png




Step 4.
Select the Add Input (Plus) icon from the tool box.
VCount2.png




Step 5.
Virtual Input Properties - Enter Count for the Description - select Count for the Type - ensure Enabled is check marked.
VCount3.png




Step 6.
Select Save & Exit button.
3139 11.png




Instructions - Standard Count


Step 1.
Select the PSM or TIM that you setup the Virtual Input on in the Common Steps - select the Edit button.
3139 4.png




Step 2.
Select the Monitoring Points tab.
Reason1.png




Step 3.
Select the Add Sampler icon from the toolbox.
VCount5.png




Step 4.
Sampler Properties - setup the monitoring point as shown below:
VCount6.png
Sampler Name - enter Count.
Mode - select Standard Sampler.
Type - select Count.
Trigger - select As Occurs.
Input - select Count - this is the Virtual Input setup in the beginning of the guide.
Color - select default.




Step 5.
Select Save & Exit button.
3139 11.png




Step 6.
You will need to update the TIM/PSM, CLICK HERE for instructions.




Step 7.
Example of what the Touch Screen will display.
StndrdCount1.png
Not Active - press the Start Count button to enable a count.
StndrdCount2.png
Active Count - press the Count button to add a count - press the End Count button to disable the count.




Instructions - Linked Count


Step 1.
Select the PSM or TIM that you setup the Virtual Input on in the Common Steps - select the Edit button.
3139 4.png




Step 2.
Select the Monitoring Points tab.
Reason1.png




Step 3.
Select the Add Process icon under the Monitoring Points tab if a process does not already exist.
CountPSM5.png




Step 4.
Process Properties - setup the monitoring point as shown below:
CountPSM6.png
Process Name - enter Work.
Mode - select Process.




Step 5.
With the Process Selected in the root - select the Add Sampler icon from the toolbox.
VCount5.png




Step 6.
Sampler Properties - setup the monitoring point as shown below:
CountPSM7.png
Sampler Name - enter Count.
Mode - select Linked Sampler.
Type - select Count.
Trigger - select As Occurs.
Input - select Count - this is the Virtual Input setup in the beginning of the guide.
Color - select default.




Step 7.
The Root should look like the image below.
CountPSM8.png




Step 8.
Select Save & Exit button.
3139 11.png




Step 9.
You will need to update the TIM/PSM, CLICK HERE for instructions.




Step 10.
Example of what the Touch Screen will display.
LinkCount1.png
Not Active - press the Start Work/Process button to enable a count.
LinkCount2.png
Active Count - press the Count button to add a count - press the End Work/Process button to disable the count.





Related - Step by Step Guides
Add a Count Button - BSC
Add a Count Button - PC Input Module
Add a Continuous Count - TIM PSM Switch Contact
Setup a Wired Input as a Count - TIM PSM Switch Contact
Add a Count to a Process - TIM, PSM
Additional Help
Submit a Ticket - https://www.versacall.com/customer-support/service-ticket
Training Videos - https://www.versacall.com/training