Overview
|
When a system requires a count to be made when there is no wired input for it, a Virtual Count button would be used. Virtual Counts added to TIM Modules, PSM Modules are different from other modules. The button will show on the touch screen/monitor as a circle with the name in the center.
|
|
Virtual Count Types
|
Standard Count - provides a button on the touch screen that allows you to start and stop when the count is active/displayed.
|
Linked Count - the count is setup as a subordinate of a Process - the count is active/displayed only after the Process has been started.
|
|
Requirements
|
1. The VT3000 Core Software installed and running on your system.
|
2. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
|
3. Hardware - TIM or PSM must be powered and communicating with the system.
|
|
Video
File:Virtual Count PSM.mkv
Instructions - Common to Both Types
Step 1.
|
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
|
|
Step 2.
|
Select the PSM or TIM that you want to add the Count Button to from the list - select the Edit button.
|
|
Step 3.
|
Select the Virtual Inputs tab.
|
|
Step 4.
|
Select the Add Input (Plus) icon from the tool box.
|
|
Step 5.
|
Virtual Input Properties - Enter Count for the Description - select Count for the Type - ensure Enabled is check marked.
|
|
Step 6.
|
Select Save & Exit button.
|
|
Instructions - Standard Count
Step 1.
|
Select the PSM or TIM that you setup the Virtual Input on in the Common Steps - select the Edit button.
|
|
Step 2.
|
Select the Monitoring Points tab.
|
|
Step 3.
|
Select the Add Sampler icon from the toolbox.
|
|
Step 4.
|
Sampler Properties - setup the monitoring point as shown below:
Sampler Name - enter Count.
|
Mode - select Standard Sampler.
|
Type - select Count.
|
Trigger - select As Occurs.
|
Input - select Count - this is the Virtual Input setup in the beginning of the guide.
|
Color - select default.
|
|
|
|
Step 5.
|
Select Save & Exit button.
|
|
Step 6.
|
You will need to update the TIM/PSM, CLICK HERE for instructions.
|
|
Step 7.
|
Example of what the Touch Screen will display.
|
Not Active - press the Start Count button to enable a count.
|
|
Active Count - press the Count button to add a count - press the End Count button to disable the count.
|
|
|
|
Instructions - Linked Count
Step 1.
|
Select the PSM or TIM that you setup the Virtual Input on in the Common Steps - select the Edit button.
|
|
Step 2.
|
Select the Monitoring Points tab.
|
|
Step 3.
|
Select the Add Process icon under the Monitoring Points tab if a process does not already exist.
|
|
Step 4.
|
Process Properties - setup the monitoring point as shown below:
Process Name - enter Work.
|
Mode - select Process.
|
|
|
|
Step 5.
|
With the Process Selected in the root - select the Add Sampler icon from the toolbox.
|
|
Step 6.
|
Sampler Properties - setup the monitoring point as shown below:
Sampler Name - enter Count.
|
Mode - select Linked Sampler.
|
Type - select Count.
|
Trigger - select As Occurs.
|
Input - select Count - this is the Virtual Input setup in the beginning of the guide.
|
Color - select default.
|
|
|
|
Step 7.
|
The Root should look like the image below.
|
|
Step 8.
|
Select Save & Exit button.
|
|
Step 9.
|
You will need to update the TIM/PSM, CLICK HERE for instructions.
|
|
Step 10.
|
Example of what the Touch Screen will display.
|
Not Active - press the Start Work/Process button to enable a count.
|
|
Active Count - press the Count button to add a count - press the End Work/Process button to disable the count.
|
|
|
|