Overview
|
A PSM, TIM or PC Input module can have Data Fields added to Alarms or Processes. This guide covers Static Lists when selecting List as the Source Type. Static Lists can only be used by the device that the list is setup on. Using this method makes each device individual from all others. This method works best when you have a specific list for a specific device that is not used on any other device.
|
|
Requirements
|
1. The VT3000 Core Software installed and running on your system.
|
2. Hardware: Coordinator must be setup, powered and communicating with the VT3000 Core Software.
|
3. Software - PC Input Module plug in must be loaded in your system.
|
4. Hardware - TIM plugin must be loaded in your system.
|
5. Hardware - TIM or PSM must be powered & communicating with the system.
|
6. The Configuration must contain at least one Alarm or Process.
|
|
Video
File:PSM Static List Data Field.mkv
Instructions
Step 1.
|
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
|
|
Step 2.
|
Select the PSM, TIM or PC Input Device that you want to add the Data Field to from the list - select the Edit button.
|
|
Step 3.
|
Select the Monitoring Points tab.
|
|
Step 4.
|
Select the Alarm or Process that you want to add a Data Field to. Our example will use the Supervisor Alarm.
|
|
Step 5.
|
Select the Add Data Field icon in the Monitoring Points tool box.
|
|
Step 6.
|
Data Field Properties - each field is explained below:
Data Field Name - enter a name, this will show on the device when the field is active.
|
Mode - Processes will have At Start & At End. Alarms will have Set, Acknowledge & Clear depending on the type of alarm. Select the appropriate setting for your configuration.
|
Source Type – select List.
|
Not Required – allows the operator to leave the field blank (no data).
|
Allow Modification Anytime – allows the operator to change the data at any time while the Process/Alarm is active.
|
Source - select Static
|
VALUE TYPE - Text - select Text - this is the only option available for a List.
|
|
|
|
Step 7.
|
Select the Items Tab that is now visible in Data Field Properties.
|
|
Step 8.
|
Select the Add Item icon in the List Items toolbox.
|
|
Step 9.
|
Enter an description for the item in the Name Field, this will show in the selection list on the touch screen.
|
|
Step 10.
|
If you want to have a different name stored in the database, check the box for Value and enter the Name you want recorded in the database. The text you entered in the Name Field will still show on the selection list on the touch screen.
|
|
Step 11.
|
Once the Data Field(s) have been setup - select the Save & Exit button to save the changes.
|
|
Step 12.
|
The PSM & TIM module will have to be updated before the Data Field will appear on the screen. Click Here for instructions on updating the module.
|
|