VT3000 - Add Indicators (PSM)

From Versacall Support
Jump to navigation Jump to search
Call Now 858-677-6766 SubmitTckBtn.png EmailUsBtn.png





GeneralHeader.png

Overview
Indicators are small icons that display on the top row of a PSM touch screen. These indicators can be configured in a number of different ways. This guide will show how to turn an indicator on based on the state of an alarm.


Requirements
See Requirements Here
1. The VT3000 Core Software installed and running on your system.
2. AMS Software installed and running on your system..
3. A Coordinator must be setup, powered and communicating with the VT3000 Core Software.
4. PSM powered and communicating with the system.





InstructionHeader.png

Step 1.
Open the VT3000 web interface – select VT3000 Core Software - log in – select Configuration – select Devices.
3177 1.png
3177 2.png
Configuration Devices




Step 2.
Select an Existing PSM configuration from the list - select the Edit button.
3177 3.png




Step 3.
Select the Virtual Indicators tab.
3177 5.png




Step 4.
Indicator Tool Box:
3177 6.png
3177 7.png
3177 8.png
3177 9.png
3177 10.png
3177 11.png
Add Indicator Delete Indicator Duplicate Indicator Copy Indicator Paste Indicator Move Indicator




Step 5.
Select to Add an Indicator.
3177 6.png




Step 6.
Indicator Properties:
3177 12.png
Description – text will show below the indicator icon on the PSM.
Default State – select what the indicator will do when nothing has occurred (On, Off, Blink, Hidden).
Default Color – select the color the indicator will be on the PSM.
Default Text – text will show inside the indicator icon when it is not hidden.




Step 7.
For our example, we will be showing a machine down alarm from another device. The indicator will be off when the alarm is cleared and will show as Red when the alarm is set.
3177 13.png




Step 8.
Select the Save & Exit button.
3177 14.png




Step 9.
A trigger in AMS must be created to turn the indicator on or off.
Open the VT3000 web interface – select AMS - log in – select Triggers.
3177 15.png
3177 16.png




Step 10.
Select the Monitor button.
3177 17.png




Step 11.
Trigger Properties:
3177 18.png
Trigger Name - enter a name for the trigger.
Period (seconds) - enter a time, in seconds, before the trigger repeats - 60 for this example.
Repeat Actions - leave box unmarked.
Disabled - leave box unmarked.




Step 12.
Select the Tags tab - select the Add icon from the toolbox.
3177 19.png




Step 13.
In the Tags section you will set up what you want to monitor. Depending on the result of the tag you will manipulate the indicator. For our example, we will be creating a State tag to monitor is an Alarm is On or Off.
3177 20.png
Name - enter a name for the tag.
Functionality - select State.
Data Source - select Monitoring Point.
Device - select the device with the machine down alarm.
Monitoring Point - select the Machine Down alarm.
Result - select Integer.




Step 14.
Select the Conditions tab - select the Plus icon from the conditions tool box. This is where we will setup what is to happen when the Tag is in a specific state.
3177 21.png




Step 15.
Condition Properties/Setup:
3177 22.png
Field 1 - enter the name of the tag created using a tilde symbol first.
Operator - select the less greater than symbol.
Field 2 - enter the number zero.
Action - click on the Add Action button.




Step 16.
Condition Action Properties/Setup:
3177 23.png
What - select Modify Indicator.
Device - select the device that the indicators were added to in Step 6.
Indicator - select the indicator.
State - select On.
Color - select Red.
Text - leave the field blank.




Step 17.
Select the Plus icon from the conditions tool box.
3177 21.png




Step 18.
Condition Properties/Setup:
3177 25.png
Field 1 - enter the name of the tag created using a tilde symbol first.
Operator - select the equals symbol.
Field 2 - enter the number zero.
Action - click on the Add Action button.




Step 19.
Condition Action Properties/Setup:
3177 26.png
What - select Modify Indicator.
Device - select the device that the indicators were added to in Step 6.
Indicator - select the indicator.
State - select Off.
Color - select Red.
Text - leave the field blank.




Step 20.
Click on the Save & Exit button.
3177 27.png




Step 21.
The setup is complete. You will need to update the configuration on the device. Ensure that you test your setup.
Click Here for instructions on updating the configuration





RelatedHowTos.png
Select a Guide Here
VT3000 - Data Field Overview
VT3000 - Add a Key Input Data Field - PSM
VT3000 - Add a Shared List Data Field - PSM
VT3000 - Add a Static List Data Field - PSM
VT3000 - Add an Alarm to PSM
VT3000 - Add Alarm Label
VT3000 - Add Alarm by Reason
VT3000 - Add Communications
VT3000 - Add Process
VT3000 - Add a Data Field to a Process
VT3000 - Add an Alarm to a Process
VT3000 - Add Virtual Count - TIM & PSM
VT3000 - Install PSM with IO




SearchHeader.png




VC Footer.png
Follow Us On LinkedIn View our Blog